Elite Software Chvac ver. 7.01.41

Posted By: webgurru
Elite Software Chvac ver. 7.01.41

Elite Software Chvac ver. 7.01.41 | Win32 | Size: 16,65 Mb

Chvac quickly and accurately calculates the maximum heating and cooling loads for commercial buildings. The cooling loads can be calculated with either the CLTD method or the new RTS (Radiant Time Series) method. The program allows an unlimited number of zones which can be grouped into as many as 100 air handling systems. Chvac automatically looks up all cooling load and correction factors necessary for computing loads. In addition, it can look up outdoor design weather data for over 2000 cities located around the world. There is also provision for editing the weather data as well as adding data for other cities. Comprehensive reports list the general project data, detailed zone loads, air handler summary loads, outside air loads, total building loads, building envelope analysis, tonnage requirements, CFM air quantities, chilled water flow rates (if applicable), and complete psychrometric data with entering and leaving coil conditions. Other outstanding features include ASHRAE Standard 62 analysis, automatic building rotation, 360 degree wall orientations, tilted glass, exterior shading, internal operating load profiles, variable indoor design temperatures, people diversity, pretreated outside air, seasonal infiltration and ventilation rates, reheat loads, duct gains and losses, and return air plenums.

Features:
* Calculates Peak Heating & Cooling Loads
* Determines Building Tonnage and Room CFM Requirements, and Runout Duct Sizes
* Uses either the RTS or CLTD calculation method
* Computes CFM Air Quantities With Psychrometrics
* Calculates from Manually Entered Data or Directly from Floor Plans Created with Drawing Board (sold separately)
* Links with Elite Software's Energy Audit and EZDOE Energy Programs
* Transfers data to the eQUEST and PowerDOE Energy Analysis Programs
* Allows 30 Walls, 30 Windows, and 12 Roofs per Zone
* Automates Compliance with ASHRAE Standard 62
* Calculates in both Metric and English Units
* Converts any project from English to Metric units and vice-versa
* Allows Simultaneous Infiltration and Ventilation
* Calculates Runout and Main Trunk Duct Sizes
* Selects Equipment from ARI/GAMA Databases
* Allows Virtually Unlimited Number of Zones
* Zones May be Optionally Grouped Under VAV Boxes
* Prints Numerous Color Pie Charts and Bar Graphs
* Creates Spreadsheet Output File